View wishlist“JA-152A Wireless internal siren to an AC socket” has been added to your wishlist
Roll over image to zoom in
Click to open expanded view
JA-110M Bus module for magnetic detectors – 2 inputs
SKU: JA-110M
Share To:
WhatsApp
Facebook
The JA-110M bus module is used to connect wired magnetic door/window detectors to the bus and contains two independent inputs programmable to be NC/NO or using a balancing resistor.
JA-110M Bus module for magnetic detectors – 2 inputs
Allows you to set a minimum time for alarm activation (0.5 s, 1 s, 2 s or 5 s).
The detector communicates with and is powered by the control panel bus. The detector is addressable and occupies two positions in the system.
SMART MEMORY indication (SMI) provides a visual (LED) verification of detector triggering. SMI is reset via the keypad.
Technical specifications
Power | 12 V bus (9 … 15 V) |
---|---|
Current consumption in standby (quiescent) | 5 mA |
Current consumption for choice of cable | 5 mA |
Maximum length of cable to the detector input | 3 m |
Dimensions | 100 x 40 x 24 mm |
Classification | grade 2 according to EN 50131-1, EN 50131-3 |
Environment | EN 50131-1. general indoor |
Operating temperature range | -10 to 40 ° C |
Complies with /th> | EN 50130-4, EN 55022 |
Be the first to review “JA-110M Bus module for magnetic detectors – 2 inputs” Cancel reply
Reviews
There are no reviews yet.